Unfortunately, due to the low display resolution, the product comparison is not possible.
std-opt ProEco
ProBasic
ProEnergy
Service life temporary solution medium-term solution < 2 years permanent > 2 years
Field(s) of application construction site accommodation, construction site offices, toilet and shower blocks, temporary solution during renovations/alterations office buildings, schools or kindergartens, temporary solution during alterations/renovations office and administration buildings, schools, kindergartens; new, as an annexe, on top of others
Design fully galvanised welded steel frame, sandwich walls with PU core steel frame with sectional sheet facade steel frame with moulded walls and a coffered facade
TECHNICAL DATA      
- Structural engineering calculation for 3 floors 3 floors 3 floors
- Live load 2,0 kN/m² 2,0–5,0 kN/m² 2,0–5,0 kN/m²
- Snow load 1,0 kN/m 1,0–2,5 kN/m² 1,0–2,5 kN/m²
- Fire protection - F30 - F90 (Optional) F30 - F90 (Optional)
Heat transfer coefficient pursuant to DIN EN ISO 10211 / in the bay section      
- Roof (W/m²K) U = 0,459 W/m²K*
(0,387 W/m²K in the bay section)
U = 0,506 W/m²K*
(0,452 W/m²K in the bay section)
U = 0,178 W/m²K*
(0,175 W/m²K in the bay section)
- Wall (W/m²K) U = 0,380 W/m²K*
(0,380 W/m²K in the bay section)
U = 0,681 W/m²K*
(0,515 W/m²K in the bay section)
U = 0,232 W/m²K*
(0,184 W/m²K in the bay section)
- Floor (W/m²K) U = 0,602 W/m²K*
(0,351 W/m²K in the bay section)
U = 0,611 W/m²K*
(0,299 W/m²K in the bay section)
U = 0,261 W/m²K*
(0,198 W/m²K in the bay section)
* Calculation pursuant to DIN EN ISO 10211 thermal bridges in building engineering      
Dimensions
     
- Length 1,518 / 3,000 / 6,058 m 3,000 -12,192 m 6,058 - 14,646 m
- Width 2,438 / 3,000 m 2,500 / 3,000 m 2,500 / 3,000 m
- Exterior height 2,800 m – exterior height over spreader slab: 2,810 m 2,800 m – other dimensions upon request 3,000 - 3,250 m – other dimensions upon request
- Clear ceiling height 2,500 m 2,500 m 2,500 - 2,750 m
VERSIONS
FRAME
     
- fully galvanised steel frame haken    
- welded steel frame, steel-shot-blasted and painted   haken haken
ROOF
- with a galvanised sectional sheet and inlying drainage

haken

haken

haken
FLOOR
FLLOR STRUCTURE WITH
- chipboard


haken


haken


haken
- panel plus plus plus
- cement-bound chipboard plus plus plus
FLOOR COATED WITH:
- GRP (glass-fibre reinforced plastic)

plus

plus

plus
Bodenbelag mit:
- PVC

haken

haken

haken
- Linoleum   plus plus
- Teppichboden   plus plus
FLOORING WITH
- Sandwich walls with PU core

haken
   
- Exchangeable wall elements plus plus  
- Sectional sheet galvanised   haken haken
OUTER DOOR
- Aluminium sandwich

haken
   
- Steel 1- or 2-leaved plus haken haken
- Aluminium 1- or 2-leaved   plus plus
WINDOWS
- With insulation glazing and outside shutters

haken

haken

haken
- With insulation glazing and outside sun protection   plus plus
INTERIOR PANELLING
- Sheet steel galvanised, polyester-coated with a magnetic surface

haken
   
- With a coated wood-based board (“Blauer Engel” certificate)   haken haken
- With plaster-based boards, wallpaper and paintwork   plus plus
ELECTRICAL INSTALLATIONS
- CEE input and output with fuse box per module

haken

haken

haken
- Central connection with main distribution board and feed-in through the floor   plus plus
HEATING SYSTEM
- Electrical

haken

haken

haken
- Individual gas heaters plus plus  
- Central hot-water heating   plus plus
SANITARY INSTALLATIONS
- Visible with visible piping

haken

haken

haken
- Concealed behind face walls, with a concealed installation system   plus plus
Cookies make it easier for us to provide you with our services. With the usage of our services you permit us to use cookies.